• 烧伤创面深度的诊断技术和方法
  •  

    Technique and method for diagnosis of burn depth

    纪晓峰 

      致力于烧伤研究的医生们一直试图对烧伤创面的深度进行准确地分类和诊断[1].从二十世纪六十年代开始,陆续出现了多种诊断技术和方法用于烧伤深度的诊断,但由于各种诊断技术的局限性和医院的条件所限,目前这些技术在临床上并未得到全面的推广.大多数医生仍偏好于采用临床判断而不辅助以仪器,特别是出现了采用切削痂和植皮手术处理深度创面的外科治疗手段后,对于更准确判断深度创面的需求似乎显得不太迫切,仪器的辅助诊断反而更加不吸引医生,尽管各种诊断技术在某些方面是具有一定的优势的.……

    作者简介:纪晓峰(1972~),男(汉族),山东淄博人,1994年毕业于山东滨州医学院临床医学系,1997年毕业于第二军医大学病理专业,硕士,2000年毕业于解放军总医院烧伤外科专业,博士. 中国中西医结合学会烧伤专业委员会委员.
    作者单位:纪晓峰(中国中西医结合学会烧伤专业委员会,北京,100053) 

    参考文献:

    [1]Jackson DM. A historical review of the use of local physical signs in burns. Br J Plast Surg. 1970, 23:211 ~ 218.
    [2]Sheridan RL, Schomaker KT, Lucchina LC, Hurley J, et al.Burn depth estimation by use of indocyanine green fluorescence: Initial human trial. J Burn Care Rehabil, 1995, 16:602~604.
    [3]Winter GD. Histological aspects of burn wound healing.Burns, 1974, 1: 191~196.
    [4]Lawrence J. C.. The perinecrotic zone in burns and its influence on healing. Burns, 1974, 1: 197~206.
    [5]Jackson DM and Stone PA. Tangential excision and grafting of burns. The method and review of fifty consecutive cases. Br J Plast Surg, 1972, 25: 416~426.
    [6]Alsbjorn B, Micheels J, Sorensen B. Laser Doppler Flowmetry measurements of superficial dermal, deep dermal and subdermal burns. Scand J Plast Recoustr Surg. 1984, 18: 75~79.
    [7]Niazi ZBM, Essex TJH, Papini R, Scott D, McLean NR,Black MJM. New Laser Doppler Scanner. A valuable adjunct in burn depth assessment. Burns, 1993, 19 (6): 485 ~489.
    [8]Latarjet J. A simple guide to burn treatment. Burns, 1995,21 (3): 221 ~ 225.
    [9]Jackson DM. The diagnosis of the depth of burning. Br J Surg, 1953, 44: 588~596.
    [10]Yeong EK, Mann R, Goldberg M, Engrav L, Heimbach D.Improved accuracy of burn wound assessment using Laser Doppler. J Trauma: Inj Inf Crit Care, 1996, 40 (6): 956~ 962.
    [11]Gursu KG. An experimental study for diagnosis of burn depth. Burns, 1978, 4 (2): 97~103.
    [12]Pape SA. Vascular cutaneous study with colour Laser Doppler Imaging. Congreso Nacional De La Sociedad Espanola De Quemaduras, Barcelona, Spain. 1996.
    [13]Kahn AM, McCrady VL, Rosen VJ. Burn wound biopsy.Scand J Plast Reconstr Surg, 1979, 13, 53 ~ 56.
    [14]Loebl EC, Marvin JA, Heck EL, Curreri PW, Baxter CR.The method of quantitative burn- wound biopsy culture and its routine use in the care of the burned patient. Am J Clin Pathol, 1974, 61: 20.
    [15]Pruitt BA, Foley FD. The use of biopsies in burn patient care. Surgery, 1973, 73: 887.
    [16]Lawson RN, Wlodek G, Webster DR. Thermographic assessment of burns and frostbite. Canada Med Assoc J. 1961,84: 1129.
    [17]Mladick R, Georgiade N, Thorne F. A clinical evaluation of the use of thermography in determining degree of burn injury.Plast Reconstr Surg. 1966, 38 (6): 512 ~ 518.
    [18]Anselmo VJ and Zawacki BE. Infra Red Photography as a diagnostic tool for the burn ward. Proc Soc Photo Optical Instr Engrs. Quantitative Imagery in the Biomed Science- Ⅱ,1973, 8: 181.
    [19]Hackett M. E.. The use of thermography in the assessment of depth of burn and blood supply in flaps, with preliminary reports on its use in deep Dupuytren's contracture and treatment of varicose ulcers. Br. J. Plast. Surg. 1974, 27,311.
    [20]Mason B. R., A. J. Graff and S. P. Pegg. Colour thermography in the diagnosis of the depth of burn injury. Burns,1974, 7:197 ~ 202
    [21]Liddington MI, Shakespeare PG. Timing of the thermographic assessment of burns. Burns, 1996, 22 (1): 26 ~ 28.
    [22]Cole R. P, Jones SG, Shakespeare PG. Thermographic assessment ofhand burns. Burns, 1990, 16 (1): 60~63.
    [23]Anselmo VJ, Zawacki BE. Effect of evaporateive surface cooling on thermographic assessment of burn depth. Radiology, 1977a, 123: 331~332.
    [24]Newman P, Pollock M, Reid WH. A practical technique for the thermographic estimation of burn depth: A preliminary report. Burns, 1981, 8 (1): 59~63.
    [25]Waxman K, Lefcourt N, Achauer B. Heated laser Doppler flow measurements to determine depth of burn injury. Am J Surg. 1989; 157: 541~543.
    [26]Essex TJH and Byrne PO. A Laser Doppler Scanner for imaging blood flow in skin. Journal of Biomedical Eng, 1991,13: 189~ 194.
    [27]Pape SA. An audit of the use of Laser Doppler Imaging(LDI) in the assessment of burn wound depth. Abs. British Burns Assoc. 31st mtg. Sheffield, U. K. 1998.
    [28]Pape SA, Skouras CA, Byrne PO. An audit of use of laser Doppler imaging (LDI) in the assessment of burns of intermediate depth. Burns 2001, 27: 233 ~ 239.
    [29]Droog E. J., W. Steenbergen, F. sjoberg. Measurement of depth of burns by laser Doppler perfusion imaging. Burns,2001, 27:561 ~568.
    [30]Bull JP, Lennard - Jones. The impairment of sensateion in burns and its clinical application as a test of the depth of skin loss. Clinical Science, 1949, 8: 155.
    [31]Bennett JE, Dingman RO. Evaluation of burn depth by the use of radioactive isotopes: An experimental study. Plastic & Reconstr Surg, 1957, 20 (4): 261~272.
    [32]Kalus AM. Application of Ultrasound in assessing burn depth. Lancet, 1979, 28: 188~189.
    [33]Wachtel TL, Leopold GR, Frank HA, Frank DH. B-mode ultrasonic echo determination of depth of thermal injury.Burns, 1986, 12:432 ~ 437.
    [34]Iraniha S, Cinat ME, VanderKam VM, Boyko A, Lee D,Jones J, Achauer BM. Determination of burn depth with noncontact Ultrasonography. J Burn Care Rehabil, 2000, 21:333 ~ 338.
    [35]Anselmo VJ and Zawacki BE. Multi Spectral Photographic Analysis- A new quantitative tool to assist in the early diagnosis of thermal burn injury. Ann Biomed Eng. 1977b, 5:179 ~ 193.
    [36]Werner Eisenbeiβ, Jorg Marotz, Jens - Peter Schrade. Reflection- optical multispectral imaging method for objective determination of burn depth. Burns, 1999, 25: 697~704.
    [37]Stranc M. F., Sowa M. G. Abdulrauf B. and Mantsch H.H.. Assessment of tissue viability using near - infrared spectroscopy. Burns, 1998, 51: 210~217.
    [38]Heimbach D M, Afromowitz M A, Engrav L H, Marvin J A, Perry B, 1984, Burn Depth Estimation- Man or Machine. J Trauma, 24 (5), 373~ 378.
    [39]Afromowitz MA, Van Liew GS, Heimbach D. Clinical evaluation of burn injuries using an optical reflectance technique.IEEE Trans Biomed Eng. 1987; 34: 114~ 117.
    [40]Afromowitz MA, Callis JB, Heimbach DM, DeSoto LA, Norton MK. Multispectral imaging of burn wounds: A new clinical instrument for evaluating burn depth. IEEE Trans Biomed Eng. 1988; 35: 842 ~ 850.
    [41]Nettelblad H, Thuomas K- A, Sjoberg F. Magnetic resonance imaging: A new diagnostic aid in the care of highvoltage electrical burns. Burns, 1996, 22 (2): 117~119.
    [42]Dingwall JA. A clinical test for differentiating second from third degree burns. Ann Surg, 1943, 118: 427~429.
    [43]Gatti JE, LaRossa D, Silverman DG, Hartford CE. Evaluation of the burn wound with perfusion fluorometry. J Trauma,1983, 23 (3): 202~206.
    [44]Green HA., Dominic Bua, Anderson RR, Nishioka NS.Burn depth estimation using indocyanine green fluorescence.Arch Dermatol, 1992, 128: 43~49.
    [45]Still JM, Law EJ, Klavuhn KG, IslandTC, Holtz J. Z. Diagnosis of burn depth using laser- induced indocyanine green fluorescence: a preliminary clinical trial. Burns, 2001, 27:364 ~ 371.